Xennovate Hydrocolloid Wound Bandage, Ostomy, and Skin Attachment Technology Highlights

See briefs of our tech highlights below...
stacks_image_CDFB5873-CA94-4064-85EF-58E957DB9559
xm18c out-absorbs world hydrocolloids by nearly five times it's own weight, when fully submerged in saline solution for 72 hours | All competitors studied dissolved into solution in less than 12 hours.
stacks_image_96B0B265-E775-4E08-8487-F46AE23115E5
Compare attributes of top three Xen18 formulations.
stacks_image_8DC7BD22-B4D5-4F37-8688-06EFBC243501
xm18s —> a new medical adhesive formulation, custom-designed and patented, in response to customers requests for a skin-friendly adhesive with extremely aggressive shear adhesion.
stacks_image_25ACDE20-93BA-4392-B922-B5413AD9CA99
xm18e, Xennovate's "Encore" formulation, remains a workhorse formulation serving ostomy adhesive needs, as well as skin attachments requiring higher than normal sheer adhesion.
stacks_image_51707B03-66A0-4462-8BDF-A38E6DDDD3C8
xm18o, for ostomy 2-piece systems seeking adhesive ring wear times of one week or more.
stacks_image_8A48C577-63A2-482B-B487-4F87D0A18A36
Please check out our Technical Brief covering the physical metrics for our roll stock. These are our "standards," although Xennovate prides itself on responding to the special needs of its customers — If you don't see what you need, ask.
stacks_image_A55D352C-D9AB-4B87-935B-A561B0D59C11
Not only does Xennovate's EverLift RemovEZj + PULL-TAB reduce removal forces by over 30% in its standard thickness products, the PULL-TABS enables easier and faster applications, as well as far easier removals of sticky and gooey bandages.
stacks_image_968B4DAD-5B87-470B-8D80-4F23F5FAC000
Use of skin-friendly hydrocolloids avoids the higher costs of alternatives.
stacks_image_15F75C54-8B9B-4BAF-AC73-7D7DE4197EC2
Adhesive strength of standard Xen18 formulations consistently matches key competition.
stacks_image_0949C69C-2AF0-4607-950F-CFECA7C81240
  • EverLift RemovEZ + PULL-TAB technology enables a conductive netting placed at the skin adhesive interface and extending beyond the edge of the dressing for access to the PULL-TAB
  • This electro-conductive PULL-TAB could connect with the electrode leads
  • EverLift RemovEZ technology enables removal force reductions of over 30% for standard thickness products.